Capacity: 5t to 50t
Steel ball loading, strong restoration ability
Easy complete installation, high weighing accuracy
OIML C3 certificate
Truck scale
Railway scale
Blending scale and all kinds of weighing apparatus
Rated capacity(t) | L | L1 | L2 | L3 | W | W1 | W2 | H | H1 | H2 | C1 | C2 | C3 |
5 | 224 | 125 | 80 | 45 | 135 | 100 | 10 | 168.8 | 11 | 20 | Φ68 | Φ30 | Φ18 |
10,15,20,25,30 | 240 | 125 | 80 | 45 | 135 | 100 | 10 | 223.5 | 11 | 20 | Φ85~88 | Φ30 | Φ18 |
40 | 240 | 125 | 80 | 45 | 135 | 100 | 10 | 239.5 | 11 | 20 | Φ88 | Φ30 | Φ18 |
50 | 340 | 160 | 124 | 45 | 160 | 124 | 10 | 260 | 11 | 20 | Φ98 | Φ40 | Φ22 |
Rated capacity: 5ton to 50ton | Operating temperature range: -30 to +70℃ |
Rated output:2.0±0.002mv/v | Maximum safe overload;150% OF R.C |
Combined error: ±0.03% F.S | Ultimate safe overload;200% OF R.C |
Non-repeatability: ±0.02% F.S | Recommended Excitation;10 to 12V DC |
Non-linearity: ±0.02% F.S | Maximum Excitation;15V DC |
Hysteresis error: ±0.02% F.S | Environment protection: IP68 |
Zero balance: ±1% F.S | Input impedance: 750±10Ω |
Creep error(30minutes): ±0.02% F.S | Output impedance: 702±3Ω; 703±5Ω(cable≥15m); |
Temperature effect on zero: ±0.02% F.S | Insulation resistance at 50V DC: ≥5000MΩ |
Temperature effect on output: ±0.02% F.S | Material: nickel-plated alloy steel; |
Compensated temperature range: -10 to +40℃ | Cable length: 5.2meter(5t);8meter(10t); 10meter(15t);10/12meter(20t);12/16meter(25t~50t),diameter 6mm |